SPECIFICATION
GENERAL |
|
| Temperature range | AECQ100 GRADE1 (-40 to +125˚C) |
| CPU | 32 bits automotive, 90MIPS |
| Reverse polarity protection | Yes, internal |
| Operating voltage | 6-22V, immunity to transients according to ISO 7637 |
| Enclosure | IP 60, bespoke CNC machined aluminium |
| Size (mm) and weight(g) | 131x112x32.5, 345g |
| Connectors | 1 x 39 Automotive connector,
1 x M6 stud for battery connection |
| PC communication | CAN (ECUMASTER USBtoCAN, PEAK CAN, KVASER) |
OUTPUTS |
|
| High current outputs | 10 x 25A(cont.), 6 x 15A(cont.) with overcurrent and overheating protection. Outputs may be paired to increase continuous current capability. Current and voltage is measured for each output |
| Total current output | 150A continuous |
| Output current control step | 100mA |
| Wipers output | Dedicated output with wiper braking feature |
| +5V | Monitored 5V, 500mA output for powering external sensors. |
INPUTS |
|
| Analog inputs | 16 inputs, 10 bit resolution, 0-5V (protected), with software selectable 10K Ohm pullup and pulldowns |
| CAN Keypads | 2 x Ecumaster keypads (4, 6, 8, 12 keys) |
OTHER |
|
| Output state indication | 16 bicolour LEDs |
| Accelerometer/Gyroscope | 3D accelerometer with 3D gyroscope for logging and crash detection |
| Real time clock | Yes, super capacitor for backup power (up to 3 days) |
CAN BUS |
|
| CAN interface | 2 x CAN2.0 A/B |
| CAN standard | CAN2.0 A/B – 125, 250, 500, 1000 kbps |
| Input/output stream | User defined with bit masking,
up to 100 input messages |
LOGGING* |
|
| Logging memory | 256 Mbytes |
| Logging speed | Variable, defined per channel, up to 500Hz |
FUNCTIONS |
|
| Logical operators | AND, OR, NOT, XOR, >, <, =, >=, <=, !=, isTrue, isFalse, Toggle, Flash, Pulse |
| Number of functions | 100 |
| Number of operations | 250 |
| Update frequency | 500Hz |
| Special functions | Wipers, blinkers |
*Version PMU-16DL